Marquez - Boiler Operator - San Pascual, Philippines

Norlan Marquez

San Pascual, Philippines

Services

Boiler Operator

Summary:

• Operates and controls the 300BHP Clever Brooks Firetube Boiler, Wastewater, Water, Fire Water system (Engine Pump), Cooling Tower systems and Water softening, Reverse Osmosis and Deaerator system.
• Plan, conduct and assist Semi-Annual and Annual Preventive Maintenance at Boiler, Economizer, De-aerator, Reverse Osmosis and Water softener.
• Monitors utilities parameters, and make necessary adjustments on valves and other means of control.
• Conducts daily, weekly and monthly monitoring checklist.
• Conducts boiler and water treatment chemical laboratory analysis such as pH, Total Dissolved Solid, Hardness and Conductivity.
• Conducts inventory and monitors the usage of WWTP materials, industrial salts, anti-corrosion, boiler system and other utilities chemicals, and generates PR when re-ordering volume is met and follow-up delivery to the supplier.
• Waste water treatment process monitoring (Aeration, Clarifiers, Clear well, Blowers, Sand Filters and Filter Press).
• Performs Waste water Laboratory analysis such as pH, Chemical Oxygen Demand, Color, Ammonia, Phosphate, and nitrate.
• Vibration checking for pumps and motors.
• Conducts repair and troubleshooting of equipment related to the operation of Boiler, WWTP and other utility systems.
• Dismantling and installing pumps and motor.
• Provides hot/cold work permit in performing work order.
• Gas testing of surroundings before hot work.
• Prepare a plan and schedule for preventive maintenance and repair activity of the utilities equipment.
• Supervises contractor’s activities especially during maintenance shutdown and other PM works.
• Submits and provides monthly and year-end consumption report to Maintenance Group Leader.
• Submits necessary environmental related monthly report to Environment, Health and Safety Group Leader

Work History

BOILER Operator / UTILITIES SPECIALIST II

STEPAN PHILIPPINES INC

From July 2008

Cocochem Agro Industrial Park,
Bauan, Batangas (043 727-2828)
July 7, 2008 up to present

DUTIES AND RESPONSIBILITIES:
• Operates and controls the 300BHP Clever Brooks Firetube Boiler, Wastewater, Water, Fire Water system (Engine Pump), Cooling Tower systems and Water softening, Reverse Osmosis and Deaerator system.
• Plan, conduct and assist Semi-Annual and Annual Preventive Maintenance at Boiler, Economizer, De-aerator, Reverse Osmosis and Water softener.
• Monitors utilities parameters, and make necessary adjustments on valves and other means of control.
• Conducts daily, weekly and monthly monitoring checklist.
• Conducts boiler and water treatment chemical laboratory analysis such as pH, Total Dissolved Solid, Hardness and Conductivity.
• Assign as Project Engineer in 300BHP Clever Brooks Firetube Boiler SPI and 40 cubic meter Diesel Tank Project from September 5, 2009 to November 20, 2009.
➢ Supervises the contractor's in their daily activities.
➢ Check the pipings, valves, steam traps, check valves and y-strainer that installed as required by SPI pipe specification.
➢ Verifies the orientation of piping based on isometric and P&ID drawing.
➢ Conducts hydrostatic testing, air blowing of the piping, radiographic and dye penetrant testing of welding joint, hammer check of tighten of bolts, pop test of safety relief valve and punch listing after the testing.
• 300HP Cleaver Brooks boiler commissioning.
• 60,000 lbs capacity water softener system commissioning.
• Reverse Osmosis system commissioning (28,000 GPD)
• Deaerator commissioning
• Boiler and other equipments installation monitoring.
• Act as Assistant Safety Officer from July 2008 - May 2010.
• Conducts inventory and monitors the usage of WWTP materials, industrial salts, anti-corrosion, boiler system and other utilities chemicals, and generates PR when re-ordering volume is met and follow-up delivery to the supplier.
• Waste water treatment process monitoring (Aeration, Clarifiers, Clear well, Blowers,...

PLC Operator / Tank Farm Operator

STEPAN PHILIPPINES QUATERNARIES, INC

October 2006 - April 2008

Cocochem Agro Industrial Park, Bauan, Batangas
October 15, 2006 - April 30, 2008

DUTIES AND RESPONSIBILITIES:
• Monitors and operates the process through PLC.
• Observes variations in operating conditions and interprets meter and gauge readings.
• Unload raw materials in tank farm from Isotank to storage tank such as Tri-ethanol Amine, Fatty Acid, and Isopropyl Alcohol.
• Load finished product from storage tank to Isotank.

OIC kitchen (Kitchen II)

OIC Kitchen

October 2004 - September 2006

DUTIES AND RESPONSIBILITIES:
• Supervises all kitchen crew.
• Monitors the operation and cleanliness of the kitchen.
• Monitors and forecasts the meats and vegetables to be use.
• Provides daily, monthly and year-end inventory.

Utilities Specialist II

Preventive Maintenance

January 2003 - November 2003

DUTIES AND RESPONSIBILITIES:
• Assigned on mechanical maintenance work
• Operate hydraulic torque and tensioning machine.
• Pull-out, repair, conditioning and re-installation of valve.
• Pull-out, repair, cleaning, re-installation/aligning of pump and motor
• Observes variations in operating conditions and interprets meter and gauge readings.
• Vibration checking for pumps and motors.
• Conducts repair and troubleshooting of equipment related to the operation.
• Line-breaking, water flushing, air blowing and hydro-static testing of pipe line.
• Blinding / de-blinding of pipe line, pumps, heat exchanger, and other related vessel.

Projects

Construction and Commissioning 300 Boiler Horse Power

• Assign as Project Engineer in 300BHP Clever Brooks Firetube Boiler SPI and 40 cubic meter Diesel Tank Project from September 5, 2009 to November 20, 2009.
 Supervises the contractor’s in their daily activities.
 Check the pipings, valves, steam traps, check valves and y-strainer that installed as required by SPI pipe specification.
 Verifies the orientation of piping based on isometric and P&ID drawing.
 Conducts hydrostatic testing, air blowing of the piping, radiographic and dye penetrant testing of welding joint, hammer check of tighten of bolts, pop test of safety relief valve and punch listing after the testing.
• 300HP Cleaver Brooks boiler commissioning.
• 60,000 lbs capacity water softener system commissioning.
• Reverse Osmosis system commissioning (28,000 GPD)
• Deaerator commissioning
• Boiler and other equipments installation monitoring.
• Act as Assistant Safety Officer from July 2008 – May 2010.

Qualifications & Certifications

Mechanical Engineering Technology

BATANGAS STATE UNIVERSITY

High School level

STA. TERESA COLLEGE

Batangas State University, Philipinnes

ADVANCED BUSINESS CONSULTANCY CENTRE

BOLBOK ELEMENTARY SCHOOL

Skillpages has been acquired by Bark.com!

Bark.com is pioneering the way people find local services. Skillpages is the world’s premier directory of service providers.

Find out more


Are you sure that you want to leave?

   
Supported Countries
Choose your country

×