Muniswamy - Blood Bank Technician - Bangalore, KA, India

Karnan Muniswamy

Bangalore, KA, India


Blood Bank Technician

Work History

processing technician


January 2008 - July 2013

CRYO-SAVE (INDIA) PRIVATE LIMITED, Bangalore Approved by (Drug control Gov't of Karnataka), lSO 9001:2008, AABB, NABL Accredited, as well as GMP from WHO Certified company)
• Processing of Umbilical Cord blood by using SEPAX Automated Cell Processing System (Bio Safe)
• Cryofreezing of Cord Blood Cells using Controlled -Rate freezer for long time storage.
• Enumeration of Hematopoietic stem cells by Flow Cytometer.
• Screening of maternal blood for Transfusion Transmissible Infectious disease using fully automated micro plate ELISA processor.
• Microbiological Culture assay of Processed Cord Blood using Bactec 9120 (BD).
Instrument handled* SEPAX(Bio safe) Automated Cell Processing System
* Bactec-9120* Bio-safety cabinet* Controlled rate freezer* Particle counter
* Liquid Nitrogen Dewar(Cryo Storage)* Flow Cytometer
* Pentra XL 80(Hematology Analyzer)* Refrigerated centrifuge
* Cryofuge (Blood bank centrifuge)* Elisa Automated Analyser



From August 2008

Presently working in cryosave india pvt ltd (Stem cells Bank) for five years. since 2008

Blood Bank Technician

Dr.B.R.Ambedkar Medical College and Hospital

January 1996 - January 2004

nine years
Worked in Life Care Blood Bank and Components as a Blood Bank Technician for 1 years

Worked in Sarvodaya Hospital Blood Bank as a Blood Bank technician for 1 years

Worked in Dr. Rajkumar Blood Bank as Blood Bank technician for 1 years

Worked in fortis Hospital as a blood bank technician for four months.


Processing & Extration of stemcell from umbilical cord blood

Processing & Extration of stemcell from umbilical cord blood by using Automated cell processer Instrument called (SEPAX).
Counting the Mono Nucleated cell with post processing cord blood. with the help of Automated Haemotology cell counter (PENTRA XL 80).
Screening the Maternal Blood for Antigen Antibody for HIV,HCV.VDRL.CMV.HTLV.
Calculating the viability for CD34 By using the Instrument called FLOWCYTOMETRY.
Storing the processed samples in dewar under -190 degree celcius which contains Liquid Nitrogen in vapour phase.

Qualifications & Certifications

Vivekananda College of JOC

Skillpages has been acquired by! is pioneering the way people find local services. Skillpages is the world’s premier directory of service providers.

Find out more

Supported Countries
Choose your country